Do not stretch during installation.
Roof anchor installation instructions.
Always install the anchor device so no part of the device is less 2 5 m from the edge of the roof or opening.
Slopes 4 12 and more a lay out anchordeck synthetic roofing underlayment horizontally parallel to the eave with the printed side up.
In general roof anchors should be installed on roofs or structures that are made of wood and sheathing.
The silicone will spread and adhere creating a seal.
Reliable roofing is a professional commercial roofing contractor that can provide roof anchor installation services in lake zurich il and the north chicago suburbs.
The users must read and abide by the manufacturer s instructions for each element of the system.
Installation of this roof anchor must be certified by a qualified person or engineering service.
Metal roofing is also available in the form of shingles.
Each roof anchor installation must be independently capable of sustaining this load.
If the material is not able to support 5 000 lbs.
Install the panel so that the short lip overlaps the large lip.
Applied in any direction permitted by the restraint system when in use.
Screw the new panel in place as described.
Installation guidelines for different slopes categories are listed below.
Continue adding panels until the roof is covered.
Both permanent and temporary roof anchor points are available.
During installation and assembly of the anchor device ensure that the installer is not less that 2 m from any edge or opening.
Lay flat cap nail flat.
You may need to cut panels to fit angles using a circular saw with a metal saw blade.
If two roof anchors are installed onto a roof structure each anchor location must be independently capable of supporting 5 000 lbs.
Anchor points are usually installed on the roof and are used to connect lanyards lifelines and other forms of tie off which prevent a worker from falling.
Roof anchors installed for restraint applications must be attached to a roof member capable of sustaining a static load of at least 3 000 lbs.
3 0 operation and use.
Minimum tensile load a qualified person must confirm that the support structure maintains a safety factor of two as per osha 1926 502.
More than one roof anchor is installed to a roof structure the strengths given in a or b above must be met at each roof anchors installation point independently.
2 way roof anchor installation instructions this product is part of a personal fall arrest system.
The roof material must be capable of supporting a minimum tensile load of 5 000 lbs.
Roof anchors can be as simple as a d ring connection or as complex as a complete lifeline system.